---
product_id: 735921215
title: "UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action"
brand: "uhppote"
price: "510 zł"
currency: PLN
in_stock: true
url: https://www.desertcart.pl/products/735921215-uhppote-9-28vdc-conventional-manual-call-point-fire-reset-push
store_origin: PL
region: Poland
---

# Dual action activation Key lock security Bright activation indicator UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action

**Brand:** uhppote
**Price:** 510 zł
**Availability:** ✅ In Stock

## Summary

> 🚨 Stay ahead of danger with precision-triggered safety!

## Quick Answers

- **What is this?** UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action by uhppote
- **How much does it cost?** 510 zł with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.pl](https://www.desertcart.pl/products/735921215-uhppote-9-28vdc-conventional-manual-call-point-fire-reset-push)

## Best For

- uhppote enthusiasts

## Why This Product

- Trusted uhppote brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Secure Key Lock:** Prevents accidental resets and unauthorized access for peace of mind.
- • **Dual Action Activation:** Push in then pull down for deliberate, fail-safe emergency triggering.
- • **Clear Visual Confirmation:** Bright yellow 'ACTIVATED' indicator ensures instant status recognition.
- • **Robust Emergency Response:** Designed for quick, reliable fire or emergency reporting in any facility.
- • **Conventional Compatibility:** Seamlessly integrates with standard fire alarm control panels.

## Overview

The UHPPOTE 9-28VDC Manual Call Point is a dual-action emergency alarm station designed for conventional fire alarm systems. Featuring a secure key lock, push-in/pull-down activation, and a bright yellow 'ACTIVATED' indicator, it ensures reliable and clear emergency signaling. Note: Requires connection to an alarm control panel to function.

## Description

Operation: The manual call points provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal(non-alarm) position manually(by hand) or by closing the station's front cover, which automatically resets the switch. Loop design and wiring: The fire alarm control panel Zone wire can be connected to terminal loop(+), loop(-) unpolarized wire. If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal loop(+),loop(-). Installation: Note: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting indoor wall Attach mounting base to wall at 1.5 meter's(59in) high Connect field wiring to terminals To attach product to mounting base Secure product by tightening the one mounting screws in the front of the product housing. Specifications:Non UL Listed Operating voltage range: 9-28VDC Volts Alarm resistance: 470ohm/1W Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: -10?~50? (14?~122?)Dimensions (LxWxH): 140x104x45mm / 5.51"x4.09"x1.77" Net Weight: 220g / 0.44lb Package: 1 x Fire alarm call point 2 x Keys 1 x English manual

## Features

- Non UL Listed
- Key lock available; Dual Action
- The HC102 conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches
- Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of
- Note: Call point can't work alone, need work with alarm control panel

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B01NGYTFAS |
| Alarm | Audible, Visual |
| Best Sellers Rank | #2,088 in Home Security Systems |
| Brand | UHPPOTE |
| Built-In Media | Fire alarm call point |
| Color | Black, Red |
| Customer Reviews | 4.4 4.4 out of 5 stars (533) |
| Item Dimensions D x W x H | 1.77"D x 4.09"W x 5.51"H |
| Item Type Name | Fire alarm call point |
| Item Weight | 220 Grams |
| Manufacturer | UHPPOTE |
| Model Number | HC102 |
| Operating Humidity | 93 percent |
| Power Source | dc |
| Product Style | Call Point |
| UPC | 616010526319 |
| Unit Count | 1 Count |
| Upper Temperature Rating | 50 Degrees Celsius |

## Product Details

- **Brand:** UHPPOTE
- **Style:** Compact
- **Power Source:** Corded Electric
- **Item Weight:** 220 Grams
- **Alarm:** Audible
- **Operating Humidity:** 93 percent
- **Manufacturer:** UHPPOTE
- **UPC:** 616010526319

## Images

![UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action - Image 1](https://m.media-amazon.com/images/I/71CuxgdCCrL.jpg)
![UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action - Image 2](https://m.media-amazon.com/images/I/81y4uREzCOL.jpg)
![UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action - Image 3](https://m.media-amazon.com/images/I/71AgoxmoErL.jpg)
![UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action - Image 4](https://m.media-amazon.com/images/I/81eUSidQtyL.jpg)
![UHPPOTE 9-28VDC Conventional Manual Call Point Fire Reset Push In Pull Down Emergency Alarm Station Dual Action - Image 5](https://m.media-amazon.com/images/I/71ZofJhz0ZL.jpg)

## Questions & Answers

**Q: Where can i buy the wire? I thought it came with it**
A: You should get the wire seperately. It support wire range is 12AWG to 22AWG, so you could search and get the wire on amazon.

**Q: How much volts does it consume**
A: 9-28VDC could do the job.

**Q: Where should I connect the 9 volt battery?**
A: Well, you put the positive and the negative wire to the pull station and the battery aswell and you can connect it to the fire alarm

**Q: What is the model number**
A: The model number of this product is UT-HC102. Thanks.

## Frequently Bought Together

- UHPPOTE Wired Emergency Fire Alarm Station 9-28VDC Conventional Dual Action Manual Call Point
- Fire Alarm Siren Security Horn Buzzer DC9V-24V Sound and Light Fire Warning Strobe Siren for Single Action Manual Pull Station or Alarm System
- QWORK Fire Alarm, 12 / 24V DC Wired Sound and Light Fire Alarm Warning Strobe Siren Horn, Sound Alarm Security System Sensor

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.pl/products/735921215-uhppote-9-28vdc-conventional-manual-call-point-fire-reset-push](https://www.desertcart.pl/products/735921215-uhppote-9-28vdc-conventional-manual-call-point-fire-reset-push)

---

*Product available on Desertcart Poland*
*Store origin: PL*
*Last updated: 2026-04-24*